ST PXS-008S-20

4 sided column encasement single layer up to 600mm deep. Board to board fix.

Further Information

Fire Performance to EN 13381-4-(up to): 60 minutes
Max Steel Section Factor: 300 A/V
Number Of Sides Exposed: 4

Applications:

  • For the protection of hot-rolled structural steel
  • Suitable for internal and unheated spaces

Benefits:

  • EN classification covering a wide scope of application
  • Can be easily decorated if required
  • Limiting steel temperatures ranging from 300°C to 700°C
  • Board to board fixing, for faster installation whilst maximising useable space in the building