Vertical Shaftwall System RNS 206

2 x 15mm GTEC Fire Board, GTEC CH1990/B CH-Studs at 600mm centres, 1 x 19 mm GTEC Fire Core Board

Further Information

Application:

Siniat GTEC Shaftwall systems can provide fire resistance upto 120mins to BS 476-22 (dependent on system), see Siniat Drywall Manual or contact Siniat Technical Services for more details

Benefits:

  • No scaffolding required with system designed to be erected from one side of shaft only
  • High strength system resists pressure changes likely in shafts and voids

Commercial Name: Vertical Shaftwall System RNS 206
Thickness: 120 mm
Weight per m²: 43 kg/m²
Fire performance to BS 476-22: 120 min
Maximum Height: 5600 mm
rw (Sound Insulation): 43 dB
Strength Duty rating (to BS5234): Severe
Innovative, Smart & Efficient Solutions
Tested & Certified Solutions