Vertical Shaftwall System RNS 110

2 x 15mm GTEC Fire Board, GTEC CH1960/B CH-Studs at 600mm centres, 25mm 16kg/m³ glass mineral wool,1 x 19mm GTEC Fire Core Board.

Further Information

Application:

Siniat GTEC Shaftwall systems can provide fire resistance upto 120mins to BS 476-22 (dependent on system), see Siniat Drywall Manual or contact Siniat Technical Services for more details

Benefits:

  • No scaffolding required with system designed to be erected from one side of shaft only
  • High strength system resists pressure changes likely in shafts and voids

Commercial Name: Vertical Shaftwall System RNS 110
Thickness: 90 mm
Weight per m²: 39 kg/m²
Insulation Type: Glass wool, Mineral wool
Insulation Thickness: 25 mm
Fire performance to BS 476-22: 120 min
Maximum Height: 5100 mm
rw (Sound Insulation): 47 dB
Strength Duty rating (to BS5234): Severe